1.
J Clin Med ; 13(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38398417

RESUMO

Objectives: This study aimed to create a three-dimensional histological reconstruction through the AI-assisted classification of tissues and the alignment of serial sections. The secondary aim was to evaluate if the novel technique for histological reconstruction accurately replicated the trabecular microarchitecture of bone. This was performed by conducting micromorphometric measurements on the reconstruction and comparing the results obtained with those of microCT reconstructions. Methods: A bone biopsy sample was harvested upon re-entry following sinus floor augmentation. Following microCT scanning and histological processing, a modified version of the U-Net architecture was trained to categorize tissues on the sections. Detector-free local feature matching with transformers was used to create the histological reconstruction. The micromorphometric parameters were calculated using Bruker's CTAn software (version 1.18.8.0, Bruker, Kontich, Belgium) for both histological and microCT datasets. Results: Correlation coefficients calculated between the micromorphometric parameters measured on the microCT and histological reconstruction suggest a strong linear relationship between the two with p-values of 0.777, 0.717, 0.705, 0.666, and 0.687 for BV/TV, BS/TV, Tb.Pf Tb.Th, and Tb.Sp, respectively. Bland-Altman and mountain plots suggest good agreement between BV/TV measurements on the two reconstruction methods. Conclusions: This novel method for three-dimensional histological reconstruction provides researchers with a tool that enables the assessment of accurate trabecular microarchitecture and histological information simultaneously.

2.
Int J Clin Pract ; 75(12): e15004, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34735743

RESUMO

OBJECTIVE: We aimed to find morphological properties of the hyoid bone, which are predominant among the patients diagnosed with obstructive sleep apnoea (OSA), and compare them with healthy individuals. METHODS: A total of 67 cone-beam computed tomography (CBCT) image sequences of patients (44 males, 23 females) diagnosed with OSA and a total of 70 multislice computed tomography (MSCT) data of non-OSA patients (45 males, 25 females) were selected in this study. DICOM images were imported into InVivo 5.1.2 (Anatomage) software. The position of the hyoid bone relative to the C3 and C4 cervical vertebrae, as well as its morphological type (B, V, U, H, D, HK-type) and its total volume was determined. RESULTS: The volumetric values of the hyoid bone of OSA patients (2384.49 ± 682.073 mm3 ) were significantly (P < .001) lower compared to the values derived from non-OSA patients (2952.96 ± 932.5 mm3 ). The difference was independent of gender, and volumetric values showed a strong significant (P < .01) difference between male OSA and non-OSA (2709.18 ± 608.05; 3157.87 ± 926.5 mm3 ) and female OSA and non-OSA patients (1763 ± 242.51 2584; 2584.12 ± 840.21 mm3 ), as well. In the case of B and V-types, the volumetric values showed significant differences (P < .05), when the OSA (2300,77 ± 622; 2166 ± 312 mm3 ) and non-OSA patients were compared (2823,48 ± 780; 3216 ± 463 mm3 ). CONCLUSION: Our results suggest that the volume of the hyoid bone might be a potential biological marker for OSA, especially in the case of B and V hyoid bone types.


Assuntos
Osso Hioide , Apneia Obstrutiva do Sono , Cefalometria , Feminino , Humanos , Osso Hioide/diagnóstico por imagem , Masculino , Apneia Obstrutiva do Sono/diagnóstico por imagem
3.
Materials (Basel) ; 14(7)2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33917513

RESUMO

The aim of this study was to compare the microarchitecture of augmented bone following maxillary sinus augmentation (MSA) after healing periods of 3 (test) and 6 (control) months using the combination of advanced platelet-rich fibrin (A-PRF) and a serum albumin-coated bone allograft (SACBA). Twenty-six patients with 30 surgical sites who required two-stage MSA were enrolled and grafted with the combination of A-PRF and SACBAs. The surgical sites were randomly allocated to the test or control group. During implant site preparation, 17 bone core biopsy samples were collected from each study group for histological, histomorphometric and micromorphometric analysis. Resonance frequency analysis was performed at the time of implant placement and 6, 8, 10, and 12 weeks postoperatively. The percentage of newly formed bone was 44.89 ± 9.49% in the test group and 39.75 ± 8.15% in the control group (p = 0.100). The results of the µCT analysis showed no significant differences in morphometric parameters between the study groups. The implant stability quotient was not significantly different between the two groups at 10 and 12 weeks postoperatively. Based on these findings, the total treatment time may be reduced by 3 months with the use of A-PRF and SACBAs for two-stage MSA.

4.
J Clin Med ; 9(2)2020 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-31973237

RESUMO

The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88-60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.

5.
Clin Oral Investig ; 23(7): 2959-2973, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30374828

RESUMO

OBJECTIVES: Functional tooth replacement and bone regeneration are parts of the daily practice in modern dentistry, but well-reproducible and relatively inexpensive experimental models are still missing. We aimed to develop a new small animal model to monitor osseointegration utilizing the combination of multiple evaluation protocols. MATERIAL AND METHODS: After cutting the tail between the C4 and C5 vertebrae in Wistar rats, costume made, parallel walled, non-threaded implants were placed into the center of the tail parallel with its longitudinal axis using a surgical guide. Osseointegration of the titanium implants was followed between 4 and 16 weeks after surgery applying axial extraction force, and resonance frequency analysis as functional tests, and histomorphometry and micro-CT as structural evaluations. RESULTS: In functional tests, we observed that both methods are suitable for the detection of the time-dependent increase in osseointegration, but the sensitivity of the pull-out technique (an approximately five times increase with rather low standard error) was much higher than that of the resonance frequency analysis. In structural evaluations, changes in the detected bone implant contact values measured by histomorphometry (yielding 1.5 times increase, with low variations of data) were more reliable than micro-CT based evaluations to screen the developments of contact between bone and implant. CONCLUSION: Our results provide evidence that the caudal vertebrae osseointegration model is useful for the preclinical evaluation of implant integration into the bone. CLINICAL RELEVANCE: The combination of the biomechanical and structural tests offers a well-reproducible small animal system that can be suitable for studying the integration of various implant materials and surface treatments.


Assuntos
Implantes Dentários , Osseointegração , Animais , Implantes Experimentais , Masculino , Ratos , Ratos Wistar , Propriedades de Superfície , Titânio
6.
Ann Ist Super Sanita ; 48(1): 49-52, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22456015

RESUMO

The aim of this study was to compare three different cone-beam CT (CBCT) instruments used in dental clinical practice with micro-CT as gold standard. Three female monkeys' (Macaca fascicularis) skulls were selected and scanned by the tested CBCT-s. The most apical visible root canal level on the CBCT images was used as reference level (RL). After the image acquisition by CBCT-s dental jaw sections were scanned by micro-CT at a resolution of 17 µm. Out of the left second and third molars 25 root canals were selected and analysed by three observers at RL and following cross sectional parameters were determined: area of the lumen, major and minor diameters, aspect ratio and mean thickness. Results suggest that only high resolution CBCT instruments allow dentists detecting the full length of the root canal.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Cavidade Pulpar/diagnóstico por imagem , Imageamento Tridimensional/instrumentação , Odontometria/métodos , Microtomografia por Raio-X/instrumentação , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/ultraestrutura , Feminino , Imageamento Tridimensional/métodos , Técnicas In Vitro , Macaca fascicularis , Dente Molar/diagnóstico por imagem , Dente Molar/ultraestrutura , Variações Dependentes do Observador , Microtomografia por Raio-X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...